Skip to main content
All CollectionsSphere XGUpload and Synchronize Projects in Sphere XG
Inspect and Fix Registration Issues in Blink Scans

Inspect and Fix Registration Issues in Blink Scans

You can correct the automatic registration of Blink scans to improve the output or fix issues.

Stefanie Zerulla avatar
Written by Stefanie Zerulla
Updated this week

When should you inspect a Blink scan registration?

  • If uploading, processing and registering Blink scans finishes successfully, you can still choose to inspect and edit the registration. However, this is not required.

  • If the uploading, processing and registering Blink scans finishes with issues, this usually due to a failure in registration, i.e. one or more scans could not be connected. In this case, you should open the inspection view and then select Edit registration.

Inspect the Registration

Click Inspect under Registration in the workflow progress bar.

The Registration - Inspect page is displayed.

On this page, you can:

  • View the registered scans in a tree view and in the viewer. You can toggle single scans on and off in the tree view by clicking the icon.

  • Show a registration quality report showing distances between points, overlap and connection details. A color code shows the overall quality at a glance: green for good quality, yellow for medium quality and red for bad quality.

  • Enter the registration editing mode.

  • Publish the scans, if the registration meets your requirements.

  • Change between top, front and right side view.

  • Change between the 2D and 3D view. In the 3D view, you can rotate the point cloud in all directions. Moving the point cloud does not affect the position of the single scans. In the 3D view, you can change between a perspective camera view and an orthographic camera view.

Edit the Registration

On this page you can manually move scans to the position you want.

Click the Edit registration button.

The Registration - Edit page is displayed.

This view has the same toolbars as the Registration - Inspect page, see above. An additional toolbar on the right side allows adding or removing connections between scans.

Note: You can only edit the registration in the 2D view.

Move and Rotate Scans

1. Click the scan you want to move.

An anchor point is displayed.

2. Click and drag that anchor point to move the selected scan to the position you want.

3. Click and drag away from the anchor point to rotate the scan.

You can zoom in and out using the mouse wheel to check the alignment.

To remove the anchor point, right-click it.

Add or Delete Connections

To add a connection:

1. Click the icon.

2. Click the first, then the second scan between which you want to establish a connection.

A connection will be established.

New connections are displayed in gray. Registered connections are displayed green, yellow or red depending on their registration result.

To delete a connection:

1. Click the icon.

2. Click the connection you want to delete.

The connection will be deleted.

To exit the the connection editing mode click the icon again.

Publish Scans

When all scans are positioned correctly:

Click the Refine & Publish button.

The scans will be registered at their new positions and published automatically if the registration is successful.

Note: If you are not able to position all scans correctly or if the Refine and Publish procedure fails, you can publish the scans as they are without registration.

For this purpose, click button Publish without refinement.

Did this answer your question?